11. Troubleshooting guide
Case 1. Starting failure
CHECK PROBABLE CAUSES ACTION
fuel tank ➞ incorrect fuel ➞ drain it and with correct fuel
fuel filter ➞ fuel filter is clogged ➞ clean
carburetor adjustment screw ➞ out of normal range ➞ adjust to normal range
sparking (no spark) ➞ spark plug is fouled/wet ➞ clean/dry
➞ plug gap is incorrect ➞ correct (GAP: 0.6~0.7mm)
spark plug ➞ disconnected ➞ retighten
Case 2. Engine starts but does not keep running/Hard re-starting.
CHECK PROBABLE CAUSES ACTION
fuel tank ➞ incorrect fuel or staled fuel ➞ drain it and with correct fuel
carburetor adjustment screw
➞ out of normal range ➞ adjust to normal range
muffler,cylinder (exhaust port)
➞ carbon is built-up ➞ wipe away
air cleaner ➞ clogged with dust ➞ wash
cylinder fin, fan cover ➞ clogged with dust ➞ clean
When your unit seems to need further service, please consult with our RedMax service shop in your area.